Suspended Floor

Suspeneded floors

 

Designed for use in timber suspended or battened floors, the Polypipe suspended floor system uses aluminium double heat spreader plates to transmit the heat evenly across the finished floor surface.

Suitable for joist widths of 300mm to 450mm, the spreader plates are simply fixed to the joist using small nails or staples. The pipe is then run into the preformed grooves of the panels which are designed to hold the pipe securely at 225mm average centers.

A layer of insulation below the panels will ensure that almost all of the heat generated passes up into the room. The Polypipe suspended floor system is also suitable for use with "sprung" flooring systems as used in sports halls etc.

Download Suspended Floor Installation Guide >>

KEY DESIGN AND ILLUSTRATION INFORMATION
Maximum Heat Output approx. 70W/m
Recommended Design Flow Temperatures 60°C
Maximum Circuit Length 80m (15mm pipe)
100m (18mm pipe)
Maximum Coverage Per Circuit
Single Heat Spreader Plates
25m2 at 300mm centres (15mm pipe)
30m2 at 300mm centres (18mm pipe)
Maximum Coverage Per Circuit
Double Heat Spreader Plates
17m2 at 225mm centres (15mm pipe)

Click Image to enlarge